Table C-11 The table below shows the difference in API for mutual exclusion semaphore management.

Panel
titleMutual Exclusion Semaphores API


µC/OS-II (os_mutex.c)µC/OS-III (os_mutex.c)Note
BOOLEAN

...


OSMutexAccept(

...


    OS_EVENT       *pevent,

...


    INT8U          *perr);

...


(1)
OS_EVENT *

...


OSMutexCreate(

...

INT8U prio,

...


    INT8U           prio,
    INT8U          *perr);
void

...


OSMutexCreate(

...


    OS_MUTEX   *p_mutex,

...


    CPU_CHAR   *p_name,

...


    OS_ERR     *p_err);
(2)
OS_EVENT *

...


OSMutexDel(

...


    OS_EVENT       *pevent,

...

INT8U opt,

...


    INT8U           opt,
    INT8U          *perr);
void

...


OSMutexDel(

...


    OS_MUTEX   *p_mutex,

...


    OS_OPT      opt,

...


    OS_ERR     *p_err);

...


void

...


OSMutexPend(

...


    OS_EVENT       *pevent,

...

INT32U timeout,

...


    INT32U          timeout,
    INT8U          *perr);
void

...


OSMutexPend(

...


    OS_MUTEX   *p_mutex,

...


    OS_TICK     timeout,

...


    OS_OPT      opt,

...


    CPU_TS     *p_ts,

...


    OS_ERR     *p_err);
(3)

...


OS_OBJ_QTY

...


OSMutexPendAbort(

...


    OS_MUTEX   *p_mutex,

...


    OS_OPT      opt,

...


    OS_ERR     *p_err);

...


INT8U

...


OSMutexPost(

...


    OS_EVENT       *pevent);
void

...


OSMutexPost(

...


    OS_MUTEX   *p_mutex,

...


    OS_OPT      opt,

...


    OS_ERR     *p_err);

...


INT8U

...


OSMutexQuery(

...


    OS_EVENT       *pevent,

...


    OS_MUTEX_DATA  *p_mutex_data);

...


(4)

...

Table C-11 Mutual Exclusion Semaphore Management API

...



Panel
bgColor#f0f0f0

(1) In µC/OS-III, there is no “accept” API, since this feature is built into the OSMutexPend() by specifying the OS_OPT_PEND_NON_BLOCKING option.

...

(2) In µC/OS-II, OSMutexCreate() returns the address of an OS_EVENT, which is used as the “handle” to the message mailbox. In µC/OS-III, the application must allocate storage for an OS_MUTEX, which serves the same purpose as the OS_EVENT. The benefit in µC/OS-III is that it is not necessary to predetermine the number of mutual-exclusion semaphores at compile time.

...

(3) µC/OS-III returns additional information when a mutex is released. The releaser takes a snapshot of the current time stamp and stores it in the OS_MUTEX. The new owner of the mutex therefore knows when the mutex was released.

...

(4) µC/OS-III does not provide query services as they were rarely used.