Signals can hold any kind of data, e.g. flags or analog data, etc. Once all messages have been defined, the user can be unconcerned about where the signal is located within a CAN message. The user can act with the CAN signals as they where in a system wide database.The CAN signal layer is configurable during compile time to minimize memory footprint and optimize performance. The following list shows the configuration parameters and their functionality:


Panel
borderWidth0
titleFigure - Signal Layer Architecture

Image Added



Configuration

Meaning

Range

Default

CANSIG_EN

This parameter enables (1) or disables (0) the CAN signal management.

0 / 1

1

CANSIG_N

This parameter defines the maximal number of managed CAN signals.

1 ... 32767

1

 


CANSIG_ARG_CHK_EN

This parameter enables (1) or disables (0) the argument checking of the CAN bus API functions.

0 / 1

1

CANSIG_MAX_WIDTH

This parameter sets the maximal width of a single integer value in byte.

1, 2 or 4

2

CANSIG_CALLBACK_EN

This parameter enables (1) or disables (0) the callback function.

0 / 1

1

CANSIG_GRANULARITY

This parameter controls if the width and position of can signal is given in bits or bytes.

BIT / BYTE

BYTE

CANSIG_STATIC_CONFIG

To reduce memory usage, declare a static signal table.

0 / 1

0

CANSIG_USE_DELETE*

To reduce memory usage don't use delete functions for signal.

0 / 1

1

The CAN signal layer is configurable during compile time to minimize memory footprint and optimize performance. The following list shows the configuration parameters and their functionality:

*Note: To use the delete function the configuration parameter CANSIG_STATIC_CONFIG must be set to 0.