µC/HTTPs

The following are the steps to follow to include µC/HTTPs into your project:

...

Module Configuration” for a detailed explanation of each configuration variables.

Instance Configuration” for more details). If your application requires a secured HTTP server instance, the http-s_instance_secure_cfg.c/.h pair of files should be used as template instead.

The configuration files includes with µC/HTTPs are templates and must be modified according to your application specific needs and constrains.

...

The OS port’s files must also be added to your project. The ports for uC/OS-II and uC/OS-III are located inside the /Micrium/Software/uC-HTTPs/OS folder.

...

If a conventional file system is used, the port should be located also inside the uC-TCPIP/FS folder. A port for the µC/FS-V4 file system is already included in this folder. If a file system other than µC/FS is used, a port template is available inside the uC-TCPIP/FS/Template folder to be customize according to your file system.

If the Static file system is used, the port for this file system is located inside uC/HTTPs. Therefore, the source files http-s_fs_static.c/.h must be include to your project. They are located inside the Micrium/Software/uC-HTTPs/FS/Static folder. Furthermore, The configuration file template http-s_fs_static_cfg.h must be copied in your application directory. This configuration file can be retrieve inside the Micrium/Software/uC-HTTPs/FS/Static/Cfg/Template folder.

...

/Micrium/Software/uC-HTTPs/
/Micrium/Software/uC-TCPIP-V2/

Since uC/HTTPs requires the use of others modules (µC/LIB, µC/CPU, RTOS, file system), the path leading to the source code of those modules must also be included in your compiler include paths. Please refer to the user manual of each module for details on the path to add.

Table of Contents
printablefalse

Prerequisites 
Anchor
Perequisites
Perequisites

Before running your first application, you must ensure that you have the minimal set of required tools and components:

  • Toolchain for your specific microcontroller.
  • Development board.
  • µC/TCP-IP stack must be installed properly (a running project). See Installing for further detail about how to install µC/TCP-IP.
  • Source code for µC/HTTP-server.

Additional Modules

µC/HTTP-server depends on other modules to run. First, it needs the presence of a RTOS. Furthermore, µC/CPU, µC/LIB, µC/Common and µC/TCP-IP modules are required.

If you are using one of the two Micriµm RTOS, complete documentation can be found for µC/OS-II and µC/OS-III. Refer to those guides for more information on the requirements, installation, configuration and running of those RTOS.

The µC/CPU module regroups the processor's hardware-dependent code. µC/CPU includes many ports for all the different CPU architectures Micriµm supports. You must therefore used the port corresponding to your specific CPU. The complete µC/CPU documentation can be found here

The µC/LIB module is the Micriµm run-time library, implementing the most common standard library functions, macros, and constants. The complete µC/LIB documentation can be found here.

The µC/TCP-IP stack is a compact, reliable, high-performance TCP/IP protocol stack which provide the socket to the HTTP application layer. The complete µC/TCP-IP  documentation can be found here.

µC/Common regroups modules use commonly by all the Micriµm products. It must therefore also be include in your project.

Downloading the Source Code
Anchor
Downloading the source code
Downloading the source code

The source code is available as open-source on Github: https://github.com/weston-embedded

Installing the Files
Anchor
Installing the Files
Installing the Files

Once all the distribution packages have been downloaded to your host machine, extract all the files at the root of your C:\ drive for instance. The package may be extracted to any location. After extracting all the files, the directory structure should look as illustrated in Figure - Directory Tree for µC/HTTP-server. In the example, all Micriµm products sub-folders shown in Figure - Directory Tree for µC/HTTP-server will be located in C:\Micrium\Software\. The Micriµm µC/OS-III RTOS has been chosen for this example.