Migrating from V4.06.02 to V4.07.00

The following is a comprehensive list of the modifications you must apply to your µC/FS projects to update them to V4.07.00 from V4.06.02. The changes are easy to make and updating your project should take a short time.

New source code

 µC/FS is comprised of mostly bugfixes and minor changes in existing modules. The first setp step is to replace every file of your project by the new ones.

API changes

NAND Generic controller Board Support Package (BSP) API changes

The NAND generic controller now supports 16-bit NAND parallel devices. The DataWr() and DataRd() functions now take the width, in bits, of the requested bus access. See Board Support Package for API details.

Existing implementations may ignore the 'width' argument and assume 8-bit operation and return error code FS_ERR_INVALID_ARG if 'width' is set, as in the following example:

 